Noticias de la Industria
nuevos productos
  • Licencia de software XBR-G6MIDR12PTPOD-32G
    Licencia de software Brocade XBR-G6MIDR12PTPOD-32G BR-MIDRMFEB-01-Z para conmutador HD-G620-24-32G

    Marca Brocade Licencia PN XBR-G6MIDR12PTPOD-32G Licencia Interior PN BR-MIDRMFEB-01-Z Lugar de origen Malasia Factor de forma F/S Interior SFP: 8 piezas 32G 850nm SW Active Brocade HD-G630-48-32G interruptor Temperatura de caja de gama baja ( °C) 0 °C Temperatura máxima de la caja (°C) 70°C Diagnóstico Digital Transmisor VCSEL Receptor PIN Voltaje Suministro 3.3--5v Conector Dual LC Garantía 1 año Condición nueva DDMI Sí Tiempo de entrega Dentro de las 24 horas Paquete Paquete original Brocade

    Lee mas
  • Conmutador de fibra óptica G720-64-32G-F
    24/64 puertos Brocade G720 Switch G720-64-32G-F Interruptor de fibra óptica

    El conmutador Brocade G720 es un conmutador Gen 7 con 64 puertos en un diseño de 1U ultradenso. Con un rendimiento 64G inigualable y un 50 % menos de latencia en comparación con la generación anterior, este conmutador ofrece un componente básico de puerto fijo diseñado para maximizar el rendimiento de los entornos flash y NVMe para cumplir con las cargas de trabajo exigentes. Con la tecnología Brocade Gen 7, Brocade G720 ofrece mucho más que mejoras en la velocidad y la latencia. Puede eliminar el dolor de administrar su centro de datos, con tecnología SAN autónoma para ofrecer una red que puede autoaprender, autooptimizarse y autorrepararse sin intervención.

    Lee mas
  • QDD-400G-ZRP-S
    Transceptores ópticos QDD-400G-ZRP-S 400G ZRP compatibles

    Descripción del producto Este transceptor QSFP-DD compatible con MSA proporciona un rendimiento 400GBase-ZR Open ZR+ a través de fibra monomodo (SMF) utilizando una longitud de onda coherente y un conector LC. Está diseñado según los estándares de MSA y está serializado de forma única y probado en aplicaciones y tráfico de datos para garantizar que se integren en su red sin problemas. El soporte de monitoreo óptico digital (DOM) también está presente para permitir el acceso a los parámetros operativos en tiempo real. Este transceptor cumple con la Ley de Acuerdos Comerciales (TAA). Respaldamos la calidad de nuestros productos y ofrecemos con orgullo una garantía limitada de por vida. Los transceptores de ProLabs cumplen con RoHS y no contienen plomo. TAA se refiere a la Ley de Acuerdos Comerciales (19 USC y 2501-2581), cuyo objetivo es fomentar el comercio internacional justo y abierto. La TAA requiere que el gobierno de los EE. UU. adquiera únicamente “productos finales fabricados en los EE. UU. o designados en un país.

    Lee mas
  • SFP 1.25G FR 15km
    Compatible Mikrotik XS+2733LC15D SFP 1.25G FR Modo único 1270nm+ 1330nm 15km Transceptores ópticos

    El kit contiene dos módulos SFP+ que se pueden usar como un par para lograr una velocidad de datos operativa de hasta 25 Gbps para distancias de hasta 15 km con un solo cable óptico. Las unidades SFP/ SFP+/ SFP28 están probadas y son compatibles con RB260GS, RB2011LS, RB2011LS-IN, RB2011UAS-IN, RB2011UAS-RM, RB2011UAS-2HnD, RB2011UAS-2HnD-IN y CCR1036-12G-4S. Las unidades también son compatibles con dispositivos SFP que no son de MikroTik. Detalles Código de producto Conector XS+2733LC15D Tasa de datos UPC de LC única Distancia 1G / 10G / 25G Formato de 15 kilómetros Modo SFP/SFP+/SFP28 Longitud de onda monomodo 1270nm + 1330nm

    Lee mas
  • QSFP+ 10G SR 15km
    Transceptores ópticos Mikrotik XS+2733LC15D 10G QSFP+ SR compatibles

    El kit contiene dos módulos SFP+ que se pueden usar como un par para lograr una velocidad de datos operativa de hasta 25 Gbps para distancias de hasta 15 km con un solo cable óptico. Transceptores ópticos SFP/ SFP+/ SFP28

    Lee mas
  • BR6505-24-8G-R/BR6505-24-16GR/BR6505-24-16GR/6505-24-0-R
    12/24 puertos Compatible Brocade BR6510 Gen 5 Fibre Channel 1U Switch BR6510-24-8G-R/BR6510-24-16GR/BR6510-24-16GR/6505-24-0-R Interruptor de fibra óptica adecuado para 57-1000117-01 /57-1000027-01/57-0000080-01/57-0000088-01/57-0000089-01

    12/24 puertos Compatible Brocade BR6510 Gen 5 Fibre Channel 1U Switch BR6510-24-8G-R/BR6510-12-8GR/BR6510- 24 -8GR Switch de fibra óptica Adecuado para 57-1000117-01/57-1000027-01/57 -0000080-01/57-0000088-01/57-0000089-01/57-1000487-01/57-0000089-01/57-1000488-01/57-1000262-01/57-1000489-01/XBR-000458 /XBR-000258/XBR-000499/XBR-000498

    Lee mas
Enterprise SSD for AI Servers: NVMe U.2 vs E1.S vs EDSFF Comparison

2026 / 08 / 10

Enterprise SSD selection for an AI server is not a contest between form-factor names. U.2, U.3, E1.S, and other EDSFF options describe a physical and electrical ecosystem that must match the server chassis, backplane, controller, carrier, cooling design, and service model. A drive that is fast on paper can still be a poor choice if it cannot be installed in the target platform, if its power profile exceeds the thermal design, or if replacement procedures are impractical. This guide gives a structured way to compare traditional 2.5-inch U.2/U.3 deployments with E1.S and related EDSFF options for AI and data-center workloads.

Define the workload before choosing a connector

Start by identifying how the SSD will be used. A boot device, metadata tier, vector database, training-data cache, checkpoint target, scratch volume, and long-term capacity tier each place different demands on latency, write endurance, capacity, recovery behaviour, and sustained quality of service. Record the expected working-set size, read/write mix, block size, queue depth, replication method, required usable capacity, and failure-domain design. AI workloads can generate short high-write periods during checkpointing or data preparation, so the specification should include sustained performance and endurance requirements rather than only a peak sequential-read figure.

Understand U.2 and U.3 in context

U.2 is commonly used to describe the 2.5-inch enterprise SSD form factor used in many server and storage systems. It remains widely deployed because existing chassis, hot-swap bays, carriers, and service procedures are familiar to operations teams. U.3 is a link-definition ecosystem associated with the SFF-8639 connector and compatible tri-mode infrastructure; it is not simply a faster label that can be assumed to work in every U.2 bay. A buyer should confirm the precise drive interface, controller or backplane support, firmware level, and carrier requirements with the platform vendor. Do not purchase a U.2 or U.3 drive based only on the physical appearance of the front bay.

Where E1.S and EDSFF fit

EDSFF stands for Enterprise and Datacenter Standard Form Factor. The family was created for data-center requirements such as serviceability, thermal management, power delivery, capacity scaling, and management. E1.S is the 1U-short member of that family and is often considered for compute servers that need a compact, front-serviceable NVMe design. Its advantages depend on the actual system: an E1.S drive requires an EDSFF-capable bay, connector, carrier, and backplane. It is not a mechanical drop-in replacement for a 2.5-inch U.2 bay. EDSFF also includes other formats, so state the exact E1.S, E1.L, E3.S, or E3.L requirement instead of writing only “EDSFF” on a purchase order.

Compatibility is a system-level check

Use a compatibility matrix that lists the server model, chassis configuration, CPU generation, BIOS or BMC revision where relevant, storage controller or PCIe switch, backplane part number, bay type, carrier or caddy, interface generation, and desired drive firmware. Ask whether the platform supports hot plug for the target bay and whether it has any vendor qualification list. For a mixed fleet, validate each server generation separately. The same SSD may be supported in one chassis but require a different carrier, power limit, or firmware policy in another. Compatibility should be proven before volume purchase through documented platform support or a controlled sample test.

Evaluate performance beyond peak throughput

Compare the performance metrics that match the workload. Sequential throughput can matter during large dataset staging, while random-read latency and tail latency may matter more for metadata, databases, and inference pipelines. For write-heavy checkpointing, review sustained write performance after cache effects, endurance rating, write amplification exposure, and the recovery process after an unplanned power event. Enterprise drives may support power-loss protection, telemetry, namespaces, encryption options, or management features, but the exact capability is model-specific. Request the current data sheet and confirm that the advertised configuration, capacity, and firmware correspond to the part number being quoted.

Thermals, power, and serviceability change the decision

Higher interface generations and denser AI-server configurations increase the importance of airflow and power budgeting. Check the drive’s maximum and typical power specifications, allowed operating temperature, heatsink or carrier requirements, and the chassis vendor’s bay-power limits. A form factor with a better thermal design cannot compensate for blocked airflow, an incorrect blanking panel, or an unsupported carrier. Also consider how a failed drive will be identified and replaced: can an operator access the bay from the front, is the slot clearly mapped to a serial number, and can the system rebuild without a disruptive maintenance window? Serviceability is part of storage availability.

Protect data with architecture, not a form factor

Neither U.2 nor E1.S automatically provides data protection. Plan the storage software, RAID or erasure-coding policy, replica placement, monitoring, backup, and replacement procedure separately. Define what happens when one drive fails, when a server is unavailable, or when a firmware update is required. For AI clusters, include the network path and the rebuild impact on training or inference workloads. The right SSD is one component of a design that remains recoverable and observable under failure conditions.

Practical selection checklist

  • Choose the workload class and required usable capacity first.
  • Confirm the exact server bay, backplane, connector, carrier, and hot-plug support.
  • Compare sustained performance, endurance, power-loss behaviour, thermals, and warranty by exact part number.
  • Validate one sample in the target platform before a volume order.
  • Document firmware, serial-number, monitoring, and replacement procedures for operations.

Decision rule for buyers

Choose U.2 or U.3 when the approved platform is built around 2.5-inch bays and the existing service model meets the capacity and performance goal. Choose E1.S or another EDSFF form factor when the server platform explicitly supports it and the density, cooling, or serviceability advantages fit the design. If the platform does not document support, pause the purchase and validate the configuration first. Topstar can quote enterprise SSD options for AI-server projects, but final selection should be based on the server vendor’s compatibility guidance and the confirmed workload requirement.