Noticias de la compañía
nuevos productos
  • Licencia de software XBR-G6MIDR12PTPOD-32G
    Licencia de software Brocade XBR-G6MIDR12PTPOD-32G BR-MIDRMFEB-01-Z para conmutador HD-G620-24-32G

    Marca Brocade Licencia PN XBR-G6MIDR12PTPOD-32G Licencia Interior PN BR-MIDRMFEB-01-Z Lugar de origen Malasia Factor de forma F/S Interior SFP: 8 piezas 32G 850nm SW Active Brocade HD-G630-48-32G interruptor Temperatura de caja de gama baja ( °C) 0 °C Temperatura máxima de la caja (°C) 70°C Diagnóstico Digital Transmisor VCSEL Receptor PIN Voltaje Suministro 3.3--5v Conector Dual LC Garantía 1 año Condición nueva DDMI Sí Tiempo de entrega Dentro de las 24 horas Paquete Paquete original Brocade

    Lee mas
  • Conmutador de fibra óptica G720-64-32G-F
    24/64 puertos Brocade G720 Switch G720-64-32G-F Interruptor de fibra óptica

    El conmutador Brocade G720 es un conmutador Gen 7 con 64 puertos en un diseño de 1U ultradenso. Con un rendimiento 64G inigualable y un 50 % menos de latencia en comparación con la generación anterior, este conmutador ofrece un componente básico de puerto fijo diseñado para maximizar el rendimiento de los entornos flash y NVMe para cumplir con las cargas de trabajo exigentes. Con la tecnología Brocade Gen 7, Brocade G720 ofrece mucho más que mejoras en la velocidad y la latencia. Puede eliminar el dolor de administrar su centro de datos, con tecnología SAN autónoma para ofrecer una red que puede autoaprender, autooptimizarse y autorrepararse sin intervención.

    Lee mas
  • QDD-400G-ZRP-S
    Transceptores ópticos QDD-400G-ZRP-S 400G ZRP compatibles

    Descripción del producto Este transceptor QSFP-DD compatible con MSA proporciona un rendimiento 400GBase-ZR Open ZR+ a través de fibra monomodo (SMF) utilizando una longitud de onda coherente y un conector LC. Está diseñado según los estándares de MSA y está serializado de forma única y probado en aplicaciones y tráfico de datos para garantizar que se integren en su red sin problemas. El soporte de monitoreo óptico digital (DOM) también está presente para permitir el acceso a los parámetros operativos en tiempo real. Este transceptor cumple con la Ley de Acuerdos Comerciales (TAA). Respaldamos la calidad de nuestros productos y ofrecemos con orgullo una garantía limitada de por vida. Los transceptores de ProLabs cumplen con RoHS y no contienen plomo. TAA se refiere a la Ley de Acuerdos Comerciales (19 USC y 2501-2581), cuyo objetivo es fomentar el comercio internacional justo y abierto. La TAA requiere que el gobierno de los EE. UU. adquiera únicamente “productos finales fabricados en los EE. UU. o designados en un país.

    Lee mas
  • SFP 1.25G FR 15km
    Compatible Mikrotik XS+2733LC15D SFP 1.25G FR Modo único 1270nm+ 1330nm 15km Transceptores ópticos

    El kit contiene dos módulos SFP+ que se pueden usar como un par para lograr una velocidad de datos operativa de hasta 25 Gbps para distancias de hasta 15 km con un solo cable óptico. Las unidades SFP/ SFP+/ SFP28 están probadas y son compatibles con RB260GS, RB2011LS, RB2011LS-IN, RB2011UAS-IN, RB2011UAS-RM, RB2011UAS-2HnD, RB2011UAS-2HnD-IN y CCR1036-12G-4S. Las unidades también son compatibles con dispositivos SFP que no son de MikroTik. Detalles Código de producto Conector XS+2733LC15D Tasa de datos UPC de LC única Distancia 1G / 10G / 25G Formato de 15 kilómetros Modo SFP/SFP+/SFP28 Longitud de onda monomodo 1270nm + 1330nm

    Lee mas
  • QSFP+ 10G SR 15km
    Transceptores ópticos Mikrotik XS+2733LC15D 10G QSFP+ SR compatibles

    El kit contiene dos módulos SFP+ que se pueden usar como un par para lograr una velocidad de datos operativa de hasta 25 Gbps para distancias de hasta 15 km con un solo cable óptico. Transceptores ópticos SFP/ SFP+/ SFP28

    Lee mas
  • BR6505-24-8G-R/BR6505-24-16GR/BR6505-24-16GR/6505-24-0-R
    12/24 puertos Compatible Brocade BR6510 Gen 5 Fibre Channel 1U Switch BR6510-24-8G-R/BR6510-24-16GR/BR6510-24-16GR/6505-24-0-R Interruptor de fibra óptica adecuado para 57-1000117-01 /57-1000027-01/57-0000080-01/57-0000088-01/57-0000089-01

    12/24 puertos Compatible Brocade BR6510 Gen 5 Fibre Channel 1U Switch BR6510-24-8G-R/BR6510-12-8GR/BR6510- 24 -8GR Switch de fibra óptica Adecuado para 57-1000117-01/57-1000027-01/57 -0000080-01/57-0000088-01/57-0000089-01/57-1000487-01/57-0000089-01/57-1000488-01/57-1000262-01/57-1000489-01/XBR-000458 /XBR-000258/XBR-000499/XBR-000498

    Lee mas
Samsung MZQL23T8HCLS-00A07: PM9A3 U.2 SSD Qualification Guide

2026 / 01 / 26

Verify the suffix before treating MZQL23T8HCLS-00A07 as a PM9A3 configuration

Samsung MZQL23T8HCLS-00A07 is commonly described as a 3.84 TB class enterprise NVMe U.2 SSD, but a shortened listing or a family name is not enough to prove that a particular drive is supported in a particular server. The full label, firmware, carrier, backplane, host platform, and vendor support policy all affect the final qualification decision.

There is an important identification point for this part number. Samsung’s publicly available PM9A3 U.2 data sheet lists the 3.84 TB model as MZQL23T8HCLS-00W07. This article therefore does not assume that the -00A07 suffix on a quotation or existing label is interchangeable with Samsung’s published -00W07 suffix. Before an order, replacement, or migration, compare the exact physical label, serial information, firmware identifier, and the server manufacturer’s supported-drive matrix. If the suffix differs, obtain written confirmation from the relevant OEM or manufacturer channel.

What Samsung officially publishes for the PM9A3 U.2 family

Samsung describes PM9A3 as a data-center SSD family for server and data-center use, built around PCIe Gen4 x4 and NVMe 1.4. The family is offered in several form factors; the U.2 version is a 2.5-inch, 7 mm device. In Samsung’s published data sheet, the 3.84 TB U.2 entry associated with MZQL23T8HCLS-00W07 is specified with up to 6,900 MB/s sequential read performance and up to 4,100 MB/s sequential write performance under the stated test conditions. These figures are useful for planning, but they apply to the published configuration and test method, not automatically to every suffix, firmware, host, or application workload.

The same distinction applies to random performance, operating power, temperature, endurance, and reliability behavior. A storage proposal should cite the exact revision of the data sheet being used, identify the particular drive label, and specify whether the quoted values are maximum, typical, sustained, or measured in the buyer’s environment. Do not convert a family-level “up to” figure into a promise for a database, virtual-machine, AI checkpoint, or video-processing workload.

Confirm the physical and electrical server path

U.2 is a practical server form factor, but it is not a universal compatibility guarantee. Verify the front or rear bay, carrier, connector, backplane, PCIe lane routing, controller or PCIe-switch path, BIOS setting, operating-system driver, and hot-service procedure of the target system. Some bays are SATA/SAS only, some are NVMe capable only in selected locations, and some need a particular backplane or cable kit. A drive that fits in a 2.5-inch carrier may still be electrically unsupported.

Document the intended host in the RFQ: server brand and model, generation, chassis, bay number, backplane part number, PCIe generation, operating system, hypervisor or storage software, and target firmware baseline. For a replacement drive, capture the original drive label, controller log, firmware, carrier, and host inventory before removal. This creates an auditable path for confirming that the new drive is a supported replacement rather than merely a mechanical match.

Map the SSD role to the actual workload

AI and data-center systems use SSDs for different jobs: operating-system boot, container images, VM datastores, model repositories, data staging, checkpoint data, logs, and capacity tiers. Each job produces a different read/write ratio, queue depth, working-set size, latency sensitivity, and durability requirement. A model repository may be dominated by parallel reads; a checkpoint target can be write intensive; a boot volume may value serviceability more than raw throughput.

Write the workload requirement before selecting capacity or performance. Record the required usable capacity after RAID, replication, and overprovisioning; the daily write rate; the recovery objective; the expected service life; and the tolerance for rebuild traffic. Use representative application testing to evaluate data-load time, checkpoint time, tail latency, and behavior during sustained writes. A short benchmark based only on peak sequential reads is not a complete enterprise-storage qualification.

Review power, cooling, and operational recovery

Samsung’s PM9A3 documentation gives separate power and thermal information for its published form factors. Those values must be checked against the actual chassis and drive revision, especially in dense GPU servers where storage bays may share constrained airflow and power budgets. Confirm carrier and heatsink requirements, airflow path, bay-power limits, operating temperature specification, cabling, and hot-swap sequence. Plan sufficient service clearance so that a drive can be identified and replaced without disturbing adjacent components.

Operational resilience belongs above the individual SSD. Protect business data through the appropriate RAID, mirroring, erasure coding, replication, backup, monitoring, and tested recovery processes. Define how a failed drive is identified, which serial number maps to which logical device, how data is rebuilt, and how firmware updates are validated. For critical workloads, include acceptance testing after installation and retain firmware and health-monitoring baselines with the handover package.

Use an evidence-based qualification checklist

  • Compare the offered drive’s complete label and suffix with Samsung’s current PM9A3 documentation; treat -00A07 and -00W07 as unconfirmed equivalents until verified.
  • Confirm capacity, U.2 form factor, PCIe/NVMe interface, firmware, carrier, and condition from the exact drive being supplied.
  • Verify the server model, bay, backplane, PCIe path, BIOS/firmware, operating system, and vendor support matrix.
  • Match sustained performance, latency, endurance, power, and cooling requirements to the actual workload rather than a headline “up to” result.
  • Run a controlled link, format, burn-in, health-monitoring, and recovery test before assigning production data.

Use Samsung documentation as the source of record

For final selection, rely on the current manufacturer data sheet and the target-system qualification guide. Samsung’s product page identifies PM9A3 as a PCIe 4.0 data-center SSD family and its data sheet identifies the published 3.84 TB U.2 part-number variant. The exact -00A07 suffix should be documented from the device label and confirmed before it is treated as equivalent to the published variant.